Model NO.: Advanced infant resuscitation radiant warmer
Three Control Modes: Pre-Warm,Manual,Baby Mode Control
LCD Display Screen: Stored and Indicate Information
Failure Alarm Indication: Yes
The Angle of Warmer Module: Adjustable Horizontally
Inclination of The Bassinet: Trendelenburg 15and Reverse Trendelenburg 20
The Panels Around Bassinet: Turn Outward
Mattress: Heatable and Controllable
LED Phototherapy Function: Yes
Trademark: WANROOEMED
Transport Package: Export Wooden Package
Specification: ISO, CE
Origin: Jiangsu, China (Mainland)
HS Code: 94029000
Hbhkn-2001 Heatable and Adjustable Neonate Resuscitation Radiant Warmer
Hbhkn-2001 Heatable and Adjustable Neonate Resuscitation Radiant Warmer
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand.
 

Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, J.V. Pole, mattress, tray and panels
 

Specification:
Power requirement: AC22OV-230V/5OHz or AC11O-120V/50-6OHz, 900VA Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro - computer
Baby mode temperature control range: 34.5-37.5°C
Accuracy of skin temperature sensor: ±0.2°C
Temperature uniformity of mattress: <= 2°C
Mattress heating control range: 25-38°C
Accuracy of mattress temperature display: ±0.7°C
Angle of warmer module: ±60°
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50"~ 1', 4'50" ~5', 9' 50"~ 10'
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: 1mW/cm2
Average value general bilirubin radiation of on the mattress effective range:
≥0.8mW/cm2
Bilirubin uniformity of radiating on the mattress effective range: >0.4
 

Environmental temperature:
Operating range: 18 °C -30°C
Ambient air movement rate:  

Product Packaging:
Package: each unit is packed into one carton
Dimension: l500mmx8l0mmxl475mm
Gross Weight: 250 Kg

 
Details:
Hbhkn-2001 Heatable and Adjustable Neonate Resuscitation Radiant Warmer
Company Information:
Hbhkn-2001 Heatable and Adjustable Neonate Resuscitation Radiant Warmer

Blood System:
Blood system is also called circulatory system.
For the treatment of diseases of the circulatory system:
According to the American Heart Association, cardiovascular disease is the leading cause of death in the United States. Because of its vastness and critical nature, it is one of the systems of the body most prone to disease.

Pin It Credit: Blood pressure check photo via ShutterstockView full size image
One of the most common diseases of the circulatory system is arteriosclerosis, in which the fatty deposits in the arteries causes the walls to stiffen and thicken the walls. According to the Mayo Clinic, the causes are a buildup of fat, cholesterol and other material in the artery walls. This can restrict blood flow or in severe cases stop it all together, resulting in a heart attack or stroke.

Stroke involves blockage of the blood vessels to the brain and is another major condition of the circulatory system, according to Mitchell Weinberg of the North Shore-LIJ Health System. [Risk factors include smoking, diabetes and high cholesterol," he noted.

Another circulatory disease, hypertension - commonly called high blood pressure - causes the heart to work harder and can lead to such complications as a heart attack, a stroke, or kidney failure, the NLM noted.

An aortic aneurysm occurs when the aorta is damaged and starts to bulge or eventually tear, which can cause severe internal bleeding. This weakness can be present at birth or the result of atherosclerosis, obesity, high blood pressure or a combination of these conditions, according to Weinberg.

Peripheral arterial disease (also known as PAD) typically involves areas of narrowing or blockage within an artery, according to Jay Radhakrishnan, an interventional radiologist in Houston, Texas. In addition, chronic venous insufficiency (also known as CVI) involves areas reflux (or backward flow) within the superficial veins of the lower extremities.

PAD is diagnosed with noninvasive testing including ultrasound, CT scan, and/or MRI. Ultrasound is the least expensive of these methods, but also gives the least amount of detail, as CT and MRI show a much higher degree of anatomic detail when identifying areas of narrowing/blockage within an artery. CVI is diagnosed with ultrasound as the venous reflux can be measured accurately by ultrasound, which ultimately guides treatment.


Blood System

Folic Acid Tablet,Iron Drug,Blood System,Enoxaparin Sodium

NOUVASANT PHARMhealth LTD. , http://www.nouvasant.com